ACSS cables are designed to improve the current carrying capacity of the line due to its improved conductivity, very low sag at high temperature, excellent immunity to vibration fatigue and better self-damping property, they are used in overhead lines for electric power transmission and distribution. In addition, they are an excellent alternative for transmission line repowering projects.
Read moreACSS/TW 1317
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 1,049.4 mm²
- Conductor diameter: 44.0 mm
- Linear weight 14SA: 4882 kg/km
- Linear weight ME/UHST: 5014.9 kg/km
- Ampacity at 200°C for 14SA: 3093 A
- Ampacity at 200°C for ME/UHST: 3058 A
- Ampacity at 250°C for 14SA: 3489 A
- Ampacity at 250°C for ME/UHST: 3449 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.026 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.026 Ohm/km
- Nominal Tensile Strength Core: 562.48 kN
ACSS/TW 228
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 201.79 mm²
- Conductor diameter: 18.02 mm
- Linear weight 14SA: 747.5 kg/km
- Linear weight ME/UHST: 760.4 kg/km
- Ampacity at 200°C for 14SA: 996 A
- Ampacity at 200°C for ME/UHST: 989 A
- Ampacity at 250°C for 14SA: 1109 A
- Ampacity at 250°C for ME/UHST: 1102 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.139 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.137 Ohm/km
- Nominal Tensile Strength Core: 63.45 kN
ACSS/TW 237.6
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 194.2 mm²
- Conductor diameter: 18.6 mm
- Linear weight 14SA: 853.2 kg/km
- Linear weight ME/UHST: 874.6 kg/km
- Ampacity at 200°C for 14SA: 997 A
- Ampacity at 200°C for ME/UHST: 986 A
- Ampacity at 250°C for 14SA: 1111 A
- Ampacity at 250°C for ME/UHST: 1099 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.142 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.139 Ohm/km
- Nominal Tensile Strength Core: 94.13 kN
ACSS/TW 265/43
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 264.6 mm²
- Conductor diameter: 20.9 mm
- Linear weight 14SA: 1045.4 kg/km
- Linear weight ME/UHST: 1066.6 kg/km
- Ampacity at 200°C for 14SA: 1200 A
- Ampacity at 200°C for ME/UHST: 1191 A
- Ampacity at 250°C for 14SA: 1339 A
- Ampacity at 250°C for ME/UHST: 1329 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.105 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.104 Ohm/km
- Nominal Tensile Strength Core: 97.76 kN
ACSS/TW 467/66
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 466.79 mm²
- Conductor diameter: 27.5 mm
- Linear weight 14SA: 1775.4 kg/km
- Linear weight ME/UHST: 1807.9 kg/km
- Ampacity at 200°C for 14SA: 1736 A
- Ampacity at 200°C for ME/UHST: 1725 A
- Ampacity at 250°C for 14SA: 1946 A
- Ampacity at 250°C for ME/UHST: 1933 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.06 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.059 Ohm/km
- Nominal Tensile Strength Core: 157.32 kN
ACSS/TW 471
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 353.93 mm²
- Conductor diameter: 26.4 mm
- Linear weight 14SA: 1839.5 kg/km
- Linear weight ME/UHST: 1897.3 kg/km
- Ampacity at 200°C for 14SA: 1523 A
- Ampacity at 200°C for ME/UHST: 1500 A
- Ampacity at 250°C for 14SA: 1706 A
- Ampacity at 250°C for ME/UHST: 1680 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.077 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.075 Ohm/km
- Nominal Tensile Strength Core: 243.51 kN
ACSS/TW 573
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 460.71 mm²
- Conductor diameter: 29.0 mm
- Linear weight 14SA: 2110.5 kg/km
- Linear weight ME/UHST: 2166.7 kg/km
- Ampacity at 200°C for 14SA: 1776 A
- Ampacity at 200°C for ME/UHST: 1757 A
- Ampacity at 250°C for 14SA: 1992 A
- Ampacity at 250°C for ME/UHST: 1970 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.06 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.059 Ohm/km
- Nominal Tensile Strength Core: 243.61 kN
ACSS/TW 687
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 535.99 mm²
- Conductor diameter: 31.8 mm
- Linear weight 14SA: 2592.5 kg/km
- Linear weight ME/UHST: 2667.1 kg/km
- Ampacity at 200°C for 14SA: 1985 A
- Ampacity at 200°C for ME/UHST: 1958 A
- Ampacity at 250°C for 14SA: 2229 A
- Ampacity at 250°C for ME/UHST: 2198 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.051 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.05 Ohm/km
- Nominal Tensile Strength Core: 312.83 kN
ACSS/TW 883
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 711.4 mm²
- Conductor diameter: 36.0 mm
- Linear weight 14SA: 3236.7 kg/km
- Linear weight ME/UHST: 3321.9 kg/km
- Ampacity at 200°C for 14SA: 2375 A
- Ampacity at 200°C for ME/UHST: 2347 A
- Ampacity at 250°C for 14SA: 2671 A
- Ampacity at 250°C for ME/UHST: 2640 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.039 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.038 Ohm/km
- Nominal Tensile Strength Core: 363.53 kN
ATHABASKA
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 987.86 mm²
- Conductor diameter: 38.1 mm
- Linear weight 14SA: 3240 kg/km
- Linear weight ME/UHST: 3273.8 kg/km
- Ampacity at 200°C for 14SA: 2796 A
- Ampacity at 200°C for ME/UHST: 2786 A
- Ampacity at 250°C for 14SA: 3147 A
- Ampacity at 250°C for ME/UHST: 3136 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.029 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.029 Ohm/km
- Nominal Tensile Strength Core: 184.7 kN
AVOCET
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 563.96 mm²
- Conductor diameter: 28.7 mm
- Linear weight 14SA: 1773.1 kg/km
- Linear weight ME/UHST: 1787.4 kg/km
- Ampacity at 200°C for 14SA: 1916 A
- Ampacity at 200°C for ME/UHST: 1912 A
- Ampacity at 250°C for 14SA: 2148 A
- Ampacity at 250°C for ME/UHST: 2144 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.05 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.05 Ohm/km
- Nominal Tensile Strength Core: 88.91 kN
BITTERN
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 644.52 mm²
- Conductor diameter: 30.99 mm
- Linear weight 14SA: 2111.9 kg/km
- Linear weight ME/UHST: 2133.9 kg/km
- Ampacity at 200°C for 14SA: 2105 A
- Ampacity at 200°C for ME/UHST: 2098 A
- Ampacity at 250°C for 14SA: 2363 A
- Ampacity at 250°C for ME/UHST: 2355 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.044 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.044 Ohm/km
- Nominal Tensile Strength Core: 123.35 kN
BLUEBIRD
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 1,092.45 mm²
- Conductor diameter: 40.89 mm
- Linear weight 14SA: 3699.4 kg/km
- Linear weight ME/UHST: 3743.3 kg/km
- Ampacity at 200°C for 14SA: 3005 A
- Ampacity at 200°C for ME/UHST: 2993 A
- Ampacity at 250°C for 14SA: 3386 A
- Ampacity at 250°C for ME/UHST: 3373 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.026 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.026 Ohm/km
- Nominal Tensile Strength Core: 234.47 kN
BLUEJAY
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 563.96 mm²
- Conductor diameter: 28.96 mm
- Linear weight 14SA: 1848.2 kg/km
- Linear weight ME/UHST: 1867.4 kg/km
- Ampacity at 200°C for 14SA: 1926 A
- Ampacity at 200°C for ME/UHST: 1920 A
- Ampacity at 250°C for 14SA: 2159 A
- Ampacity at 250°C for ME/UHST: 2153 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.05 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.05 Ohm/km
- Nominal Tensile Strength Core: 107.99 kN
BOBOLINK
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 725.09 mm²
- Conductor diameter: 32.77 mm
- Linear weight 14SA: 2375.9 kg/km
- Linear weight ME/UHST: 2400.6 kg/km
- Ampacity at 200°C for 14SA: 2277 A
- Ampacity at 200°C for ME/UHST: 2268 A
- Ampacity at 250°C for 14SA: 2557 A
- Ampacity at 250°C for ME/UHST: 2547 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.039 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.039 Ohm/km
- Nominal Tensile Strength Core: 136.76 kN
BUNTING
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 604.24 mm²
- Conductor diameter: 29.97 mm
- Linear weight 14SA: 1979.7 kg/km
- Linear weight ME/UHST: 2000.2 kg/km
- Ampacity at 200°C for 14SA: 2016 A
- Ampacity at 200°C for ME/UHST: 2009 A
- Ampacity at 250°C for 14SA: 2261 A
- Ampacity at 250°C for ME/UHST: 2254 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.047 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.047 Ohm/km
- Nominal Tensile Strength Core: 115.59 kN
CALUMET
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 286.44 mm²
- Conductor diameter: 21.84 mm
- Linear weight 14SA: 1132.6 kg/km
- Linear weight ME/UHST: 1155.5 kg/km
- Ampacity at 200°C for 14SA: 1265 A
- Ampacity at 200°C for ME/UHST: 1255 A
- Ampacity at 250°C for 14SA: 1413 A
- Ampacity at 250°C for ME/UHST: 1402 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.098 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.096 Ohm/km
- Nominal Tensile Strength Core: 105.68 kN
CARDINAL
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 483.39 mm²
- Conductor diameter: 27.43 mm
- Linear weight 14SA: 1793.2 kg/km
- Linear weight ME/UHST: 1824 kg/km
- Ampacity at 200°C for 14SA: 1767 A
- Ampacity at 200°C for ME/UHST: 1754 A
- Ampacity at 250°C for 14SA: 1979 A
- Ampacity at 250°C for ME/UHST: 1966 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.058 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.057 Ohm/km
- Nominal Tensile Strength Core: 145.53 kN
CATAWABA
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 644.52 mm²
- Conductor diameter: 30.48 mm
- Linear weight 14SA: 2026.7 kg/km
- Linear weight ME/UHST: 2043 kg/km
- Ampacity at 200°C for 14SA: 2091 A
- Ampacity at 200°C for ME/UHST: 2086 A
- Ampacity at 250°C for 14SA: 2346 A
- Ampacity at 250°C for ME/UHST: 2341 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.044 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.044 Ohm/km
- Nominal Tensile Strength Core: 101.69 kN
CHEYENNE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 591.88 mm²
- Conductor diameter: 29.46 mm
- Linear weight 14SA: 1860.8 kg/km
- Linear weight ME/UHST: 1875.8 kg/km
- Ampacity at 200°C for 14SA: 1981 A
- Ampacity at 200°C for ME/UHST: 1977 A
- Ampacity at 250°C for 14SA: 2222 A
- Ampacity at 250°C for ME/UHST: 2217 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.048 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.048 Ohm/km
- Nominal Tensile Strength Core: 93.29 kN
CHUKAR
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 901.93 mm²
- Conductor diameter: 36.83 mm
- Linear weight 14SA: 3062.6 kg/km
- Linear weight ME/UHST: 3098.8 kg/km
- Ampacity at 200°C for 14SA: 2633 A
- Ampacity at 200°C for ME/UHST: 2620 A
- Ampacity at 250°C for 14SA: 2962 A
- Ampacity at 250°C for ME/UHST: 2948 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.032 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.031 Ohm/km
- Nominal Tensile Strength Core: 198.62 kN
COLUMBIA
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 489.57 mm²
- Conductor diameter: 27.69 mm
- Linear weight 14SA: 1816.5 kg/km
- Linear weight ME/UHST: 1847.8 kg/km
- Ampacity at 200°C for 14SA: 1783 A
- Ampacity at 200°C for ME/UHST: 1772 A
- Ampacity at 250°C for 14SA: 1998 A
- Ampacity at 250°C for ME/UHST: 1986 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.057 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.057 Ohm/km
- Nominal Tensile Strength Core: 147.48 kN
CONDOR
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 402.83 mm²
- Conductor diameter: 25.15 mm
- Linear weight 14SA: 1494.2 kg/km
- Linear weight ME/UHST: 1519.9 kg/km
- Ampacity at 200°C for 14SA: 1566 A
- Ampacity at 200°C for ME/UHST: 1556 A
- Ampacity at 250°C for 14SA: 1753 A
- Ampacity at 250°C for ME/UHST: 1741 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.07 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.069 Ohm/km
- Nominal Tensile Strength Core: 121.24 kN
CUMBERLAND
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 976.36 mm²
- Conductor diameter: 39.37 mm
- Linear weight 14SA: 3618 kg/km
- Linear weight ME/UHST: 3678.9 kg/km
- Ampacity at 200°C for 14SA: 2827 A
- Ampacity at 200°C for ME/UHST: 2808 A
- Ampacity at 250°C for 14SA: 3184 A
- Ampacity at 250°C for ME/UHST: 3162 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.029 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.029 Ohm/km
- Nominal Tensile Strength Core: 293.4 kN
CURLEW
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 523.67 mm²
- Conductor diameter: 28.7 mm
- Linear weight 14SA: 1942.5 kg/km
- Linear weight ME/UHST: 1975.8 kg/km
- Ampacity at 200°C for 14SA: 1867 A
- Ampacity at 200°C for ME/UHST: 1854 A
- Ampacity at 250°C for 14SA: 2093 A
- Ampacity at 250°C for ME/UHST: 2079 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.053 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.053 Ohm/km
- Nominal Tensile Strength Core: 155.22 kN
DIPPER
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 684.81 mm²
- Conductor diameter: 32.0 mm
- Linear weight 14SA: 2243.6 kg/km
- Linear weight ME/UHST: 2266.9 kg/km
- Ampacity at 200°C for 14SA: 2194 A
- Ampacity at 200°C for ME/UHST: 2186 A
- Ampacity at 250°C for 14SA: 2464 A
- Ampacity at 250°C for ME/UHST: 2455 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.041 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.041 Ohm/km
- Nominal Tensile Strength Core: 130.99 kN
DOVE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 281.98 mm²
- Conductor diameter: 21.59 mm
- Linear weight 14SA: 1115.5 kg/km
- Linear weight ME/UHST: 1138.1 kg/km
- Ampacity at 200°C for 14SA: 1251 A
- Ampacity at 200°C for ME/UHST: 1241 A
- Ampacity at 250°C for 14SA: 1397 A
- Ampacity at 250°C for ME/UHST: 1386 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.099 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.098 Ohm/km
- Nominal Tensile Strength Core: 104.18 kN
DRAKE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 402.83 mm²
- Conductor diameter: 25.65 mm
- Linear weight 14SA: 1593.5 kg/km
- Linear weight ME/UHST: 1625.8 kg/km
- Ampacity at 200°C for 14SA: 1581 A
- Ampacity at 200°C for ME/UHST: 1570 A
- Ampacity at 250°C for 14SA: 1770 A
- Ampacity at 250°C for ME/UHST: 1757 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.069 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.068 Ohm/km
- Nominal Tensile Strength Core: 146.18 kN
FALCON
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 805.65 mm²
- Conductor diameter: 35.81 mm
- Linear weight 14SA: 2986.6 kg/km
- Linear weight ME/UHST: 3037 kg/km
- Ampacity at 200°C for 14SA: 2484 A
- Ampacity at 200°C for ME/UHST: 2470 A
- Ampacity at 250°C for 14SA: 2794 A
- Ampacity at 250°C for ME/UHST: 2778 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.035 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.035 Ohm/km
- Nominal Tensile Strength Core: 242.4 kN
FINCH
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 563.96 mm²
- Conductor diameter: 30.23 mm
- Linear weight 14SA: 2090.9 kg/km
- Linear weight ME/UHST: 2126.2 kg/km
- Ampacity at 200°C for 14SA: 1964 A
- Ampacity at 200°C for ME/UHST: 1952 A
- Ampacity at 250°C for 14SA: 2203 A
- Ampacity at 250°C for ME/UHST: 2190 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.05 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.049 Ohm/km
- Nominal Tensile Strength Core: 174.41 kN
FLICKER
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 241.7 mm²
- Conductor diameter: 19.81 mm
- Linear weight 14SA: 896.7 kg/km
- Linear weight ME/UHST: 912.2 kg/km
- Ampacity at 200°C for 14SA: 1122 A
- Ampacity at 200°C for ME/UHST: 1115 A
- Ampacity at 250°C for 14SA: 1252 A
- Ampacity at 250°C for ME/UHST: 1244 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.116 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.115 Ohm/km
- Nominal Tensile Strength Core: 74.04 kN
FRASER
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 479.69 mm²
- Conductor diameter: 27.43 mm
- Linear weight 14SA: 1676 kg/km
- Linear weight ME/UHST: 1699.3 kg/km
- Ampacity at 200°C for 14SA: 1750 A
- Ampacity at 200°C for ME/UHST: 1741 A
- Ampacity at 250°C for 14SA: 1960 A
- Ampacity at 250°C for ME/UHST: 1950 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.059 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.058 Ohm/km
- Nominal Tensile Strength Core: 118.53 kN
GENESEE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 586.76 mm²
- Conductor diameter: 29.72 mm
- Linear weight 14SA: 1927.3 kg/km
- Linear weight ME/UHST: 1947.6 kg/km
- Ampacity at 200°C for 14SA: 1981 A
- Ampacity at 200°C for ME/UHST: 1975 A
- Ampacity at 250°C for 14SA: 2222 A
- Ampacity at 250°C for ME/UHST: 2215 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.048 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.048 Ohm/km
- Nominal Tensile Strength Core: 113.52 kN
GRACKLE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 604.24 mm²
- Conductor diameter: 30.99 mm
- Linear weight 14SA: 2240 kg/km
- Linear weight ME/UHST: 2277.7 kg/km
- Ampacity at 200°C for 14SA: 2050 A
- Ampacity at 200°C for ME/UHST: 2036 A
- Ampacity at 250°C for 14SA: 2300 A
- Ampacity at 250°C for ME/UHST: 2286 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.047 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.046 Ohm/km
- Nominal Tensile Strength Core: 181.79 kN
GROSBEAK
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 322.26 mm²
- Conductor diameter: 23.11 mm
- Linear weight 14SA: 1274.5 kg/km
- Linear weight ME/UHST: 1300.3 kg/km
- Ampacity at 200°C for 14SA: 1367 A
- Ampacity at 200°C for ME/UHST: 1356 A
- Ampacity at 250°C for 14SA: 1528 A
- Ampacity at 250°C for ME/UHST: 1516 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.087 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.085 Ohm/km
- Nominal Tensile Strength Core: 116.89 kN
HAWK
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 241.7 mm²
- Conductor diameter: 20.07 mm
- Linear weight 14SA: 955.9 kg/km
- Linear weight ME/UHST: 975.2 kg/km
- Ampacity at 200°C for 14SA: 1130 A
- Ampacity at 200°C for ME/UHST: 1122 A
- Ampacity at 250°C for 14SA: 1261 A
- Ampacity at 250°C for ME/UHST: 1252 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.116 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.114 Ohm/km
- Nominal Tensile Strength Core: 89.22 kN
HEN
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 241.7 mm²
- Conductor diameter: 20.96 mm
- Linear weight 14SA: 1084.1 kg/km
- Linear weight ME/UHST: 1111.8 kg/km
- Ampacity at 200°C for 14SA: 1153 A
- Ampacity at 200°C for ME/UHST: 1140 A
- Ampacity at 250°C for 14SA: 1287 A
- Ampacity at 250°C for ME/UHST: 1273 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.115 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.113 Ohm/km
- Nominal Tensile Strength Core: 119.4 kN
HUDSON
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 586.96 mm²
- Conductor diameter: 30.48 mm
- Linear weight 14SA: 2179.4 kg/km
- Linear weight ME/UHST: 2216.9 kg/km
- Ampacity at 200°C for 14SA: 2016 A
- Ampacity at 200°C for ME/UHST: 2004 A
- Ampacity at 250°C for 14SA: 2263 A
- Ampacity at 250°C for ME/UHST: 2248 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.048 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.047 Ohm/km
- Nominal Tensile Strength Core: 174.51 kN
JAMES
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 876.9 mm²
- Conductor diameter: 37.34 mm
- Linear weight 14SA: 3251.4 kg/km
- Linear weight ME/UHST: 3306.2 kg/km
- Ampacity at 200°C for 14SA: 2628 A
- Ampacity at 200°C for ME/UHST: 2616 A
- Ampacity at 250°C for 14SA: 2958 A
- Ampacity at 250°C for ME/UHST: 2944 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.032 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.032 Ohm/km
- Nominal Tensile Strength Core: 264 kN
KETTLE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 485.01 mm²
- Conductor diameter: 26.92 mm
- Linear weight 14SA: 1589.5 kg/km
- Linear weight ME/UHST: 1606.1 kg/km
- Ampacity at 200°C for 14SA: 1743 A
- Ampacity at 200°C for ME/UHST: 1737 A
- Ampacity at 250°C for 14SA: 1953 A
- Ampacity at 250°C for ME/UHST: 1946 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.058 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.058 Ohm/km
- Nominal Tensile Strength Core: 92.9 kN
LAPWING
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 805.65 mm²
- Conductor diameter: 34.54 mm
- Linear weight 14SA: 2639.7 kg/km
- Linear weight ME/UHST: 2667.1 kg/km
- Ampacity at 200°C for 14SA: 2443 A
- Ampacity at 200°C for ME/UHST: 2433 A
- Ampacity at 250°C for 14SA: 2747 A
- Ampacity at 250°C for ME/UHST: 2735 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.035 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.035 Ohm/km
- Nominal Tensile Strength Core: 151.92 kN
MACKENZIE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 688.96 mm²
- Conductor diameter: 32.0 mm
- Linear weight 14SA: 2257.5 kg/km
- Linear weight ME/UHST: 2281 kg/km
- Ampacity at 200°C for 14SA: 2200 A
- Ampacity at 200°C for ME/UHST: 2194 A
- Ampacity at 250°C for 14SA: 2470 A
- Ampacity at 250°C for ME/UHST: 2464 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.041 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.041 Ohm/km
- Nominal Tensile Strength Core: 131.87 kN
MALLARD
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 402.83 mm²
- Conductor diameter: 26.57 mm
- Linear weight 14SA: 1792.7 kg/km
- Linear weight ME/UHST: 1838 kg/km
- Ampacity at 200°C for 14SA: 1608 A
- Ampacity at 200°C for ME/UHST: 1590 A
- Ampacity at 250°C for 14SA: 1801 A
- Ampacity at 250°C for ME/UHST: 1781 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.069 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.068 Ohm/km
- Nominal Tensile Strength Core: 198.77 kN
MARTIN
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 684.81 mm²
- Conductor diameter: 33.02 mm
- Linear weight 14SA: 2537.8 kg/km
- Linear weight ME/UHST: 2580.5 kg/km
- Ampacity at 200°C for 14SA: 2228 A
- Ampacity at 200°C for ME/UHST: 2215 A
- Ampacity at 250°C for 14SA: 2503 A
- Ampacity at 250°C for ME/UHST: 2488 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.041 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.041 Ohm/km
- Nominal Tensile Strength Core: 205.81 kN
MAUMEE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 389.25 mm²
- Conductor diameter: 24.89 mm
- Linear weight 14SA: 1445.5 kg/km
- Linear weight ME/UHST: 1470.4 kg/km
- Ampacity at 200°C for 14SA: 1534 A
- Ampacity at 200°C for ME/UHST: 1525 A
- Ampacity at 250°C for 14SA: 1717 A
- Ampacity at 250°C for ME/UHST: 1706 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.072 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.071 Ohm/km
- Nominal Tensile Strength Core: 117.56 kN
MERRIMACK
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 726.41 mm²
- Conductor diameter: 34.04 mm
- Linear weight 14SA: 2692.8 kg/km
- Linear weight ME/UHST: 2738.2 kg/km
- Ampacity at 200°C for 14SA: 2321 A
- Ampacity at 200°C for ME/UHST: 2306 A
- Ampacity at 250°C for 14SA: 2608 A
- Ampacity at 250°C for ME/UHST: 2591 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.039 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.038 Ohm/km
- Nominal Tensile Strength Core: 218.53 kN
MIRAMICHI
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 737.4 mm²
- Conductor diameter: 33.02 mm
- Linear weight 14SA: 2416.9 kg/km
- Linear weight ME/UHST: 2442 kg/km
- Ampacity at 200°C for 14SA: 2300 A
- Ampacity at 200°C for ME/UHST: 2294 A
- Ampacity at 250°C for 14SA: 2584 A
- Ampacity at 250°C for ME/UHST: 2577 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.038 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.038 Ohm/km
- Nominal Tensile Strength Core: 139.25 kN
MOHAWK
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 289.68 mm²
- Conductor diameter: 21.59 mm
- Linear weight 14SA: 1075.3 kg/km
- Linear weight ME/UHST: 1093.8 kg/km
- Ampacity at 200°C for 14SA: 1264 A
- Ampacity at 200°C for ME/UHST: 1256 A
- Ampacity at 250°C for 14SA: 1411 A
- Ampacity at 250°C for ME/UHST: 1402 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.097 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.096 Ohm/km
- Nominal Tensile Strength Core: 88.87 kN
MYSTIC
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 337.77 mm²
- Conductor diameter: 23.11 mm
- Linear weight 14SA: 1253 kg/km
- Linear weight ME/UHST: 1274.6 kg/km
- Ampacity at 200°C for 14SA: 1395 A
- Ampacity at 200°C for ME/UHST: 1386 A
- Ampacity at 250°C for 14SA: 1559 A
- Ampacity at 250°C for ME/UHST: 1549 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.083 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.082 Ohm/km
- Nominal Tensile Strength Core: 103.44 kN
NELSON
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 636.97 mm²
- Conductor diameter: 30.73 mm
- Linear weight 14SA: 2087.5 kg/km
- Linear weight ME/UHST: 2109.2 kg/km
- Ampacity at 200°C for 14SA: 2087 A
- Ampacity at 200°C for ME/UHST: 2080 A
- Ampacity at 250°C for 14SA: 2342 A
- Ampacity at 250°C for ME/UHST: 2334 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.044 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.044 Ohm/km
- Nominal Tensile Strength Core: 122 kN
ORIOLE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 170.45 mm²
- Conductor diameter: 17.6 mm
- Linear weight 14SA: 764.6 kg/km
- Linear weight ME/UHST: 784.1 kg/km
- Ampacity at 200°C for 14SA: 915 A
- Ampacity at 200°C for ME/UHST: 905 A
- Ampacity at 250°C for 14SA: 1019 A
- Ampacity at 250°C for ME/UHST: 1008 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.163 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.16 Ohm/km
- Nominal Tensile Strength Core: 85.8 kN
ORTOLAN
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 523.67 mm²
- Conductor diameter: 27.94 mm
- Linear weight 14SA: 1715.7 kg/km
- Linear weight ME/UHST: 1733.5 kg/km
- Ampacity at 200°C for 14SA: 1834 A
- Ampacity at 200°C for ME/UHST: 1828 A
- Ampacity at 250°C for 14SA: 2056 A
- Ampacity at 250°C for ME/UHST: 2048 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.054 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.054 Ohm/km
- Nominal Tensile Strength Core: 100.16 kN
OSWEGO
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 336.85 mm²
- Conductor diameter: 23.62 mm
- Linear weight 14SA: 1332.8 kg/km
- Linear weight ME/UHST: 1359.8 kg/km
- Ampacity at 200°C for 14SA: 1408 A
- Ampacity at 200°C for ME/UHST: 1397 A
- Ampacity at 250°C for 14SA: 1574 A
- Ampacity at 250°C for ME/UHST: 1562 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.083 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.082 Ohm/km
- Nominal Tensile Strength Core: 122.3 kN
OXBIRD
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 604.24 mm²
- Conductor diameter: 29.72 mm
- Linear weight 14SA: 1899.9 kg/km
- Linear weight ME/UHST: 1915.2 kg/km
- Ampacity at 200°C for 14SA: 2008 A
- Ampacity at 200°C for ME/UHST: 2002 A
- Ampacity at 250°C for 14SA: 2252 A
- Ampacity at 250°C for ME/UHST: 2245 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.047 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.047 Ohm/km
- Nominal Tensile Strength Core: 95.28 kN
PARAKEET
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 281.98 mm²
- Conductor diameter: 21.34 mm
- Linear weight 14SA: 1046 kg/km
- Linear weight ME/UHST: 1064 kg/km
- Ampacity at 200°C for 14SA: 1242 A
- Ampacity at 200°C for ME/UHST: 1234 A
- Ampacity at 250°C for 14SA: 1387 A
- Ampacity at 250°C for ME/UHST: 1378 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.099 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.098 Ohm/km
- Nominal Tensile Strength Core: 86.34 kN
PECOS
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 821.87 mm²
- Conductor diameter: 36.07 mm
- Linear weight 14SA: 3081.9 kg/km
- Linear weight ME/UHST: 3135.6 kg/km
- Ampacity at 200°C for 14SA: 2520 A
- Ampacity at 200°C for ME/UHST: 2501 A
- Ampacity at 250°C for 14SA: 2834 A
- Ampacity at 250°C for ME/UHST: 2813 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.034 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.034 Ohm/km
- Nominal Tensile Strength Core: 256.39 kN
PEE DEE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 891.08 mm²
- Conductor diameter: 36.32 mm
- Linear weight 14SA: 2920.5 kg/km
- Linear weight ME/UHST: 2950.8 kg/km
- Ampacity at 200°C for 14SA: 2612 A
- Ampacity at 200°C for ME/UHST: 2604 A
- Ampacity at 250°C for 14SA: 2938 A
- Ampacity at 250°C for ME/UHST: 2929 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.032 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.032 Ohm/km
- Nominal Tensile Strength Core: 168.24 kN
PHEASANT
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 644.52 mm²
- Conductor diameter: 32.0 mm
- Linear weight 14SA: 2389 kg/km
- Linear weight ME/UHST: 2429.2 kg/km
- Ampacity at 200°C for 14SA: 2140 A
- Ampacity at 200°C for ME/UHST: 2128 A
- Ampacity at 250°C for 14SA: 2403 A
- Ampacity at 250°C for ME/UHST: 2389 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.044 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.043 Ohm/km
- Nominal Tensile Strength Core: 193.82 kN
PHOENIX
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 483.39 mm²
- Conductor diameter: 26.67 mm
- Linear weight 14SA: 1519.8 kg/km
- Linear weight ME/UHST: 1532.1 kg/km
- Ampacity at 200°C for 14SA: 1732 A
- Ampacity at 200°C for ME/UHST: 1728 A
- Ampacity at 250°C for 14SA: 1940 A
- Ampacity at 250°C for ME/UHST: 1935 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.059 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.058 Ohm/km
- Nominal Tensile Strength Core: 77.83 kN
PLATTE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 795.01 mm²
- Conductor diameter: 33.78 mm
- Linear weight 14SA: 2499.9 kg/km
- Linear weight ME/UHST: 2520.1 kg/km
- Ampacity at 200°C for 14SA: 2405 A
- Ampacity at 200°C for ME/UHST: 2398 A
- Ampacity at 250°C for 14SA: 2702 A
- Ampacity at 250°C for ME/UHST: 2694 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.036 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.035 Ohm/km
- Nominal Tensile Strength Core: 125.42 kN
PLOVER
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 725.09 mm²
- Conductor diameter: 34.04 mm
- Linear weight 14SA: 2687.8 kg/km
- Linear weight ME/UHST: 2733.1 kg/km
- Ampacity at 200°C for 14SA: 2318 A
- Ampacity at 200°C for ME/UHST: 2303 A
- Ampacity at 250°C for 14SA: 2605 A
- Ampacity at 250°C for ME/UHST: 2588 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.039 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.038 Ohm/km
- Nominal Tensile Strength Core: 218.11 kN
POTONAC
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 789.13 mm²
- Conductor diameter: 34.29 mm
- Linear weight 14SA: 2586.2 kg/km
- Linear weight ME/UHST: 2613 kg/km
- Ampacity at 200°C for 14SA: 2410 A
- Ampacity at 200°C for ME/UHST: 2403 A
- Ampacity at 250°C for 14SA: 2709 A
- Ampacity at 250°C for ME/UHST: 2701 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.036 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.036 Ohm/km
- Nominal Tensile Strength Core: 148.95 kN
POWDER
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 1,091.33 mm²
- Conductor diameter: 40.64 mm
- Linear weight 14SA: 3696.3 kg/km
- Linear weight ME/UHST: 3740.1 kg/km
- Ampacity at 200°C for 14SA: 2998 A
- Ampacity at 200°C for ME/UHST: 2987 A
- Ampacity at 250°C for 14SA: 3378 A
- Ampacity at 250°C for ME/UHST: 3365 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.026 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.026 Ohm/km
- Nominal Tensile Strength Core: 234.4 kN
PUFFIN
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 402.83 mm²
- Conductor diameter: 24.89 mm
- Linear weight 14SA: 1430.4 kg/km
- Linear weight ME/UHST: 1451.8 kg/km
- Ampacity at 200°C for 14SA: 1558 A
- Ampacity at 200°C for ME/UHST: 1550 A
- Ampacity at 250°C for 14SA: 1743 A
- Ampacity at 250°C for ME/UHST: 1734 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.07 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.069 Ohm/km
- Nominal Tensile Strength Core: 106.89 kN
RAIL
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 483.39 mm²
- Conductor diameter: 26.92 mm
- Linear weight 14SA: 1584 kg/km
- Linear weight ME/UHST: 1600.5 kg/km
- Ampacity at 200°C for 14SA: 1740 A
- Ampacity at 200°C for ME/UHST: 1734 A
- Ampacity at 250°C for 14SA: 1949 A
- Ampacity at 250°C for ME/UHST: 1943 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.059 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.058 Ohm/km
- Nominal Tensile Strength Core: 92.53 kN
RIO GRANDE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 776.92 mm²
- Conductor diameter: 35.05 mm
- Linear weight 14SA: 2880.9 kg/km
- Linear weight ME/UHST: 2929.5 kg/km
- Ampacity at 200°C for 14SA: 2425 A
- Ampacity at 200°C for ME/UHST: 2408 A
- Ampacity at 250°C for 14SA: 2726 A
- Ampacity at 250°C for ME/UHST: 2707 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.036 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.036 Ohm/km
- Nominal Tensile Strength Core: 233.95 kN
ROOK
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 322.26 mm²
- Conductor diameter: 22.61 mm
- Linear weight 14SA: 1195.4 kg/km
- Linear weight ME/UHST: 1216 kg/km
- Ampacity at 200°C for 14SA: 1353 A
- Ampacity at 200°C for ME/UHST: 1345 A
- Ampacity at 250°C for 14SA: 1511 A
- Ampacity at 250°C for ME/UHST: 1503 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.087 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.086 Ohm/km
- Nominal Tensile Strength Core: 98.67 kN
SANTEE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 1,331.25 mm²
- Conductor diameter: 44.7 mm
- Linear weight 14SA: 4509.8 kg/km
- Linear weight ME/UHST: 4563.4 kg/km
- Ampacity at 200°C for 14SA: 3425 A
- Ampacity at 200°C for ME/UHST: 3409 A
- Ampacity at 250°C for 14SA: 3864 A
- Ampacity at 250°C for ME/UHST: 3846 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.021 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.021 Ohm/km
- Nominal Tensile Strength Core: 286.17 kN
SCHUYLKILL
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 839.8 mm²
- Conductor diameter: 35.31 mm
- Linear weight 14SA: 2752.1 kg/km
- Linear weight ME/UHST: 2780.7 kg/km
- Ampacity at 200°C for 14SA: 2513 A
- Ampacity at 200°C for ME/UHST: 2505 A
- Ampacity at 250°C for 14SA: 2825 A
- Ampacity at 250°C for ME/UHST: 2817 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.034 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.034 Ohm/km
- Nominal Tensile Strength Core: 158.47 kN
SCISSORTAIL
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 644.52 mm²
- Conductor diameter: 30.48 mm
- Linear weight 14SA: 2026.7 kg/km
- Linear weight ME/UHST: 2043 kg/km
- Ampacity at 200°C for 14SA: 2091 A
- Ampacity at 200°C for ME/UHST: 2086 A
- Ampacity at 250°C for 14SA: 2346 A
- Ampacity at 250°C for ME/UHST: 2341 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.044 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.044 Ohm/km
- Nominal Tensile Strength Core: 101.69 kN
SNOWBIRD
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 523.67 mm²
- Conductor diameter: 27.69 mm
- Linear weight 14SA: 1646.4 kg/km
- Linear weight ME/UHST: 1659.7 kg/km
- Ampacity at 200°C for 14SA: 1826 A
- Ampacity at 200°C for ME/UHST: 1821 A
- Ampacity at 250°C for 14SA: 2046 A
- Ampacity at 250°C for ME/UHST: 2040 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.054 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.054 Ohm/km
- Nominal Tensile Strength Core: 84.29 kN
ST CROIX
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 743.73 mm²
- Conductor diameter: 32.77 mm
- Linear weight 14SA: 2339.9 kg/km
- Linear weight ME/UHST: 2358.8 kg/km
- Ampacity at 200°C for 14SA: 2300 A
- Ampacity at 200°C for ME/UHST: 2294 A
- Ampacity at 250°C for 14SA: 2584 A
- Ampacity at 250°C for ME/UHST: 2577 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.038 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.038 Ohm/km
- Nominal Tensile Strength Core: 117.65 kN
SUWANEE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 486.23 mm²
- Conductor diameter: 28.19 mm
- Linear weight 14SA: 1922.5 kg/km
- Linear weight ME/UHST: 1961.4 kg/km
- Ampacity at 200°C for 14SA: 1794 A
- Ampacity at 200°C for ME/UHST: 1780 A
- Ampacity at 250°C for 14SA: 2010 A
- Ampacity at 250°C for ME/UHST: 1995 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.057 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.057 Ohm/km
- Nominal Tensile Strength Core: 173.45 kN
TERN
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 402.83 mm²
- Conductor diameter: 24.38 mm
- Linear weight 14SA: 1314.4 kg/km
- Linear weight ME/UHST: 1328.1 kg/km
- Ampacity at 200°C for 14SA: 1541 A
- Ampacity at 200°C for ME/UHST: 1536 A
- Ampacity at 250°C for 14SA: 1724 A
- Ampacity at 250°C for ME/UHST: 1718 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.07 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.07 Ohm/km
- Nominal Tensile Strength Core: 78.87 kN
THAMES
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 676.24 mm²
- Conductor diameter: 32.77 mm
- Linear weight 14SA: 2507.3 kg/km
- Linear weight ME/UHST: 2549.6 kg/km
- Ampacity at 200°C for 14SA: 2209 A
- Ampacity at 200°C for ME/UHST: 2196 A
- Ampacity at 250°C for 14SA: 2481 A
- Ampacity at 250°C for ME/UHST: 2467 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.042 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.041 Ohm/km
- Nominal Tensile Strength Core: 203.57 kN
TRUCKEE
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 695.45 mm²
- Conductor diameter: 31.75 mm
- Linear weight 14SA: 2186.6 kg/km
- Linear weight ME/UHST: 2204.2 kg/km
- Ampacity at 200°C for 14SA: 2202 A
- Ampacity at 200°C for ME/UHST: 2197 A
- Ampacity at 250°C for 14SA: 2472 A
- Ampacity at 250°C for ME/UHST: 2466 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.041 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.041 Ohm/km
- Nominal Tensile Strength Core: 109.65 kN
WABASH
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 386.51 mm²
- Conductor diameter: 25.15 mm
- Linear weight 14SA: 1528.2 kg/km
- Linear weight ME/UHST: 1559.1 kg/km
- Ampacity at 200°C for 14SA: 1540 A
- Ampacity at 200°C for ME/UHST: 1527 A
- Ampacity at 250°C for 14SA: 1723 A
- Ampacity at 250°C for ME/UHST: 1709 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.072 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.071 Ohm/km
- Nominal Tensile Strength Core: 140.07 kN
YUKON
Nexans ref.
- Packaging: Drum
- Aluminium cross-section: 625.07 mm²
- Conductor diameter: 31.75 mm
- Linear weight 14SA: 2320.7 kg/km
- Linear weight ME/UHST: 2360 kg/km
- Ampacity at 200°C for 14SA: 2103 A
- Ampacity at 200°C for ME/UHST: 2089 A
- Ampacity at 250°C for 14SA: 2361 A
- Ampacity at 250°C for ME/UHST: 2346 A
- Max. DC resistance of the conductor at 20°C - ME/UHST: 0.045 Ohm/km
- Max. DC resistance of the conductor at 20°C 14SA: 0.044 Ohm/km
- Nominal Tensile Strength Core: 188.97 kN
Description
Description
Construction
ACSS cables are designed to improve the current carrying capacity of the line due to its improved conductivity, very low sag at high temperature, excellent immunity to vibration fatigue and better self-damping property, they are used in overhead lines for electric power transmission and distribution. In addition, they are an excellent alternative for transmission line repowering projects.
ACSS cables are suitable for operating at high temperature without loosing the mechanical properties. Additionally they are suitable for corrosive environments due to the use of steel cores with 5% zinc-aluminum alloy coatings.
Note: Any other application or use not described above is considered prohibited.
Concentric conductor composed of aluminum wires 1350-H0, helically applied over ultra-high strength steel core coated with Class A zinc-5% aluminum-mischmetal alloy (Zn-5Al-MM).
Applicable standards
- ASTM B958
- ASTM B609
- ASTM B856
- ASTM B857
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Resources
Resources
Selling & delivery Information
Packaging
Reels by 1000 m. Other packaging units available upon request.
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania