XFVB Cca 0.6/1kV 2x1.5 B500 P1km

Nexans ref. 10538073

  • Packaging: Drum (500m)
  • Number of cores: 2
  • Conductor cross-section: 1.5 mm²
  • Permissible current rating in open air: 26 A
  • Voltage drop, single phase: 25.0 V/A.km

XFVB Cca 0.6/1kV 2x1.5

Nexans ref. 10538060

  • Packaging: Cut to length (m)
  • Number of cores: 2
  • Conductor cross-section: 1.5 mm²
  • Permissible current rating in open air: 26 A
  • Voltage drop, single phase: 25.0 V/A.km

XFVB Cca 0.6/1kV 2x2.5

Nexans ref. 10538062

  • Packaging: Cut to length (m)
  • Number of cores: 2
  • Conductor cross-section: 2.5 mm²
  • Permissible current rating in open air: 36 A
  • Voltage drop, single phase: 15.4 V/A.km

XFVB Cca 0.6/1kV 2x2.5 B1000 P1km

Nexans ref. 10538074

  • Packaging: Drum (1000m)
  • Number of cores: 2
  • Conductor cross-section: 2.5 mm²
  • Permissible current rating in open air: 36 A
  • Voltage drop, single phase: 15.4 V/A.km

XFVB Cca 0.6/1kV 2x2.5 B500 P1km

Nexans ref. 10538075

  • Packaging: Drum (500m)
  • Number of cores: 2
  • Conductor cross-section: 2.5 mm²
  • Permissible current rating in open air: 36 A
  • Voltage drop, single phase: 15.4 V/A.km

XFVB Cca 0.6/1kV 2x2.5 R100 P2km

Nexans ref. 10538076

  • Packaging: Ring (100m)
  • Number of cores: 2
  • Conductor cross-section: 2.5 mm²
  • Permissible current rating in open air: 36 A
  • Voltage drop, single phase: 15.4 V/A.km

XFVB Cca 0.6/1kV 2X4

Nexans ref. 10540657

  • Packaging: Cut to length (m)
  • Number of cores: 2
  • Conductor cross-section: 4 mm²
  • Permissible current rating in open air: 49 A
  • Voltage drop, single phase: 9.7 V/A.km

XFVB Cca 0.6/1kV 2X6

Nexans ref. 10540659

  • Packaging: Cut to length (m)
  • Number of cores: 2
  • Conductor cross-section: 6 mm²
  • Permissible current rating in open air: 63 A
  • Voltage drop, single phase: 6.5 V/A.km

XFVB Cca 0.6/1kV 2x10

Nexans ref. 10538070

  • Packaging: Cut to length (m)
  • Number of cores: 2
  • Conductor cross-section: 10 mm²
  • Permissible current rating in open air: 86 A
  • Voltage drop, single phase: 4.0 V/A.km

XFVB Cca 0.6/1kV 2X16

Nexans ref. 10538081

  • Packaging: Cut to length (m)
  • Number of cores: 2
  • Conductor cross-section: 16 mm²
  • Permissible current rating in open air: 100 A
  • Voltage drop, single phase: 2.2 V/A.km

XFVB Cca 0.6/1kV 3x1.5

Nexans ref. 10540643

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Permissible current rating in open air: 23 A
  • Voltage drop, single phase: 21.6 V/A.km

XFVB Cca 0.6/1kV 3x1.5 B500

Nexans ref. 10540644

  • Packaging: Drum (500m)
  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Permissible current rating in open air: 23 A
  • Voltage drop, single phase: 21.6 V/A.km

XFVB Cca 0.6/1kV 3x1.5 R100 P2km

Nexans ref. 10540646

  • Packaging: Ring (100m)
  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Permissible current rating in open air: 23 A
  • Voltage drop, single phase: 21.6 V/A.km

XFVB Cca 0.6/1kV 3x2.5

Nexans ref. 10538083

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Permissible current rating in open air: 32 A
  • Voltage drop, single phase: 13.3 V/A.km

XFVB Cca 0.6/1kV 3x2.5 B1000 P1km

Nexans ref. 10538063

  • Packaging: Drum (1000m)
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Permissible current rating in open air: 32 A
  • Voltage drop, single phase: 13.3 V/A.km

XFVB Cca 0.6/1kV 3x2.5 B500 P1km

Nexans ref. 10538077

  • Packaging: Drum (500m)
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Permissible current rating in open air: 32 A
  • Voltage drop, single phase: 13.3 V/A.km

XFVB Cca 0.6/1kV 3x2.5 R100 P2km

Nexans ref. 10538078

  • Packaging: Ring (100m)
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Permissible current rating in open air: 32 A
  • Voltage drop, single phase: 13.3 V/A.km

XFVB Cca 0.6/1kV 3x4

Nexans ref. 10540650

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 4 mm²
  • Permissible current rating in open air: 42 A
  • Voltage drop, single phase: 8.4 V/A.km

XFVB Cca 0.6/1kV 3x4 B1km

Nexans ref. 10540651

  • Packaging: Drum (1000m)
  • Number of cores: 3
  • Conductor cross-section: 4 mm²
  • Permissible current rating in open air: 42 A
  • Voltage drop, single phase: 8.4 V/A.km

XFVB Cca 0.6/1kV 3x6 B1km

Nexans ref. 10540653

  • Packaging: Drum (1000m)
  • Number of cores: 3
  • Conductor cross-section: 6 mm²
  • Permissible current rating in open air: 54 A
  • Voltage drop, single phase: 5.7 V/A.km

XFVB Cca 0.6/1kV 3x6

Nexans ref. 10540652

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 6 mm²
  • Permissible current rating in open air: 54 A
  • Voltage drop, single phase: 5.7 V/A.km

XFVB Cca 0.6/1kV 3X10

Nexans ref. 10540656

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 10 mm²
  • Permissible current rating in open air: 75 A
  • Voltage drop, single phase: 3.4 V/A.km

XFVB Cca 0.6/1kV 3X16

Nexans ref. 10538059

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 16 mm²
  • Permissible current rating in open air: 100 A
  • Voltage drop, single phase: 2.2 V/A.km

XFVB Cca 0.6/1kV 3X25

Nexans ref. 10540123

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 25 mm²
  • Permissible current rating in open air: 127 A
  • Voltage drop, single phase: 1.5 V/A.km

XFVB Cca 0.6/1kV 4x1.5

Nexans ref. 10538079

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Permissible current rating in open air: 23 A
  • Voltage drop, single phase: 21.6 V/A.km

XFVB Cca 0.6/1kV 4x1.5 B1000 P1km

Nexans ref. 10538061

  • Packaging: Drum (1000m)
  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Permissible current rating in open air: 23 A
  • Voltage drop, single phase: 21.6 V/A.km

XFVB Cca 0.6/1kV 4x1.5 B500 P0.5km

Nexans ref. 10538080

  • Packaging: Drum (500m)
  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Permissible current rating in open air: 23 A
  • Voltage drop, single phase: 21.6 V/A.km

XFVB Cca 0.6/1kV 4x2.5

Nexans ref. 10540647

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Permissible current rating in open air: 32 A
  • Voltage drop, single phase: 13.3 V/A.km

XFVB Cca 0.6/1kV 4x2.5 R100 P2km

Nexans ref. 10540648

  • Packaging: Ring (100m)
  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Permissible current rating in open air: 32 A
  • Voltage drop, single phase: 13.3 V/A.km

XFVB Cca 0.6/1kV 4x4

Nexans ref. 10538009

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 4 mm²
  • Permissible current rating in open air: 42 A
  • Voltage drop, single phase: 8.4 V/A.km

XFVB Cca 0.6/1kV 4x6

Nexans ref. 10540654

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 6 mm²
  • Permissible current rating in open air: 54 A
  • Voltage drop, single phase: 5.7 V/A.km

XFVB Cca 0.6/1kV 4x10

Nexans ref. 10538071

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 10 mm²
  • Permissible current rating in open air: 75 A
  • Voltage drop, single phase: 3.4 V/A.km

XFVB Cca 0.6/1kV 4X16

Nexans ref. 10538057

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 16 mm²
  • Permissible current rating in open air: 100 A
  • Voltage drop, single phase: 2.2 V/A.km

XFVB Cca 0.6/1kV 4x25

Nexans ref. 10540122

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 25 mm²
  • Permissible current rating in open air: 127 A
  • Voltage drop, single phase: 1.5 V/A.km

XFVB Cca 0.6/1KV 7X 1,5

Nexans ref. 10535696

  • Packaging: Cut to length (m)
  • Number of cores: 7
  • Conductor cross-section: 1.5 mm²
  • Permissible current rating in open air: 16 A
  • Voltage drop, single phase: 25.0 V/A.km

XFVB Cca 0.6/1kV 7X2,5

Nexans ref. 10540574

  • Packaging: Cut to length (m)
  • Number of cores: 7
  • Conductor cross-section: 2.5 mm²
  • Permissible current rating in open air: 23 A
  • Voltage drop, single phase: 15.4 V/A.km

Description

Description

Standards

  • National
    NBN HD 604 Part 4/Sect.G

Design

  1. Copper core, solid (Class 1) or stranded (Class 2)
  2. Cross-linked polyethylene (XLPE) insulation (X)
  3. Inner sheath
  4. Safety circuit with copper wires (*)
  5. Steel tapes (F)
  6. Fire-retardant PVC oversheath (V) - colour: Grey

(*)The cross-sectional area equal to the phase cross-section, with a maximum of 16  mm² may be used as earth conductor.

 

Installation

  • In cable tray
  • In cable duct
  • In open air if protected from direct UV rays
  • In industries
  • In houses
  • No ground laying without protection

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Insulation
XLPE (chemical)
Armour type
Steel tapes
Material of bedding
Extruded compound
Outer sheath
PVC
Sheath colour
Grey

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U
0.6/1 kV
Test voltage
4 kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Rigid
Impact resistance Max (IEC 30364-5-51)
6 J
Mechanical resistance to impacts
Normal domestic use

Usage characteristics

Usage characteristics

Bending factor when laying
12 (xD)
Field of application
Indoor, Outdoor
Operating temperature, range
0 - 60 °C
Minimum installation temperature
0 °C
Resistance to vibrations
Moderate
Chemical resistance
Medium
Water proof
Good
Metric marking
Continuous

Resources

Resources

Related families

Armoured installation cables
Halogen free armoured cables

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close