ALSECURE® PLUS Multicores 27G1,5 length to cut

Description

Description

Standards

  • International
    IEC 60228
  • National
    NBN 713-020; NBN C30-004 cat. F2; NBN-IEC 502-NAD

Application

ALSECURE® PLUS Multicores cables are designed to be used in safety systems (emergency lights, warning systems, fire fighting equipments, etc ...) in all premises open to the public (concert hall, theaters, cinemas, department stores, hospitals, schools, etc ...), in high-rises buildings, in tunnels, in industries.

ALSECURE® PLUS Multicores cables are fire resistant and fire retardant, low smoke and halogen free: in the event of fire, emitted gazes are non corrosive and have a very low toxicity.

Installation

ALSECURE® PLUS multicores cables will be installed to the wiring regulation and installation standards in force.
ALSECURE® PLUS multicores cables are not designed for buried installation.

Fire performance

  • Fire resistant according to IEC 60331, NF C 32-070 Cat. CR1, EN 50200, NBN C 30-004 F2 FR2 PH60
  • Fire retardant according to IEC 60332 Part 2 & 1, NF C 32-070 Cat. C1 & C2, EN 50266, NBN C 30-004 F2
  • Low smoke : IEC 61034, NF C 32-073, EN 50268
  • Halogen free : IEC 60754, NF C 32-074, EN 50267

Marking

ALSECURE PLUS Nber of cores & section NF-USE NEXANS 279  300/500V NF C 32-310 CR1/C1 SECURISE EFECTIS FRANCE F2 FR2 60

Core identification

White cores printed with black numbers with Y/G core

complement ALSECURE® PLUS 300/500V Multicores

Type Approval

LCIE: Laboratoire Central des Industries Electriques

Others design features

Current rating Capacities

The data are indicated for continuous duty operation and apply to:

  • Maximum conductor temperature = 90 °C
  • Nominal frequencies = 50 or 60 Hz
  • One cable in free air (on perforated trays)
  • Ambient temperature = 30 °C

Data recording from IEC 60364-5-52 (2001) or NF C 15-100 (2002)

Voltage Drop

  • The data are based on Cos alpha = 0.8

Bending Radius

  • r = 6 x maximum outer diameter

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Bare copper
Conductor flexibility
Solid class 1
Insulation
Silicon elastomer
Outer sheath
Polyolefin
Sheath colour
Orange
With Green/Yellow core
Yes
Higher heating value
6480 MJ/km
Conductor shape
Circular

Dimensional characteristics

Dimensional characteristics

Number of cores
27
Conductor cross-section
1.5 mm²
Minimum outer diameter
23.5 mm
Maximum outer diameter
29.0 mm
Approximate weight
1000 kg/km

Electrical characteristics

Electrical characteristics

Permissible current rating in open air
- A
Voltage drop, single phase
- V/A.km
Voltage drop, 3 conductors
- V/A.km
Rated Voltage Uo/U (Um)
300/500 V

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Rigid

Usage characteristics

Usage characteristics

Fire resistant
NF C 32-070 CR1
Fire retardant
NF C 32-070 C1
Flame retardant
C2, NF C 32-070
Smoke density
EN 50268
Operating temperature, range
-20 ... 60 °C
Max. conductor temperature in service
90 °C
Packaging
Cut to length

Resources

Resources

Dealer locator

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close