SXAVB Cca 0,6/1kV

Products

SXAVB Cca 10x1,5 mm²

Nexans ref. 10538235

  • Packaging: Cut to length (m)
  • Armour type: Galvanised round steel wires
  • Number of cores: 10
  • Conductor cross-section: 1.5 mm²
  • Armour thickness: 1.2 mm
  • Nominal outer diameter: 21.5 mm
  • Approximate weight: 827 kg/km
  • Permissible current rating in open air: 13 A
  • Permissible current rating when buried: 15 A
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

SXAVB Cca 10x2.5 mm² FB

Nexans ref. 10567570

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 10
  • Conductor cross-section: 2.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 20.1 mm
  • Approximate weight: 694 kg/km
  • Permissible current rating in open air: 18 A
  • Permissible current rating when buried: 20 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km

 

SXAVB Cca 12x1.5 mm² FB

Nexans ref. 10567582

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 12
  • Conductor cross-section: 1.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 19.1 mm
  • Approximate weight: 606 kg/km
  • Permissible current rating in open air: 12 A
  • Permissible current rating when buried: 15 A
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

SXAVB Cca 12x2.5 mm² FB

Nexans ref. 10567583

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 12
  • Conductor cross-section: 2.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 20.6 mm
  • Approximate weight: 760 kg/km
  • Permissible current rating in open air: 17 A
  • Permissible current rating when buried: 20 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km

 

SXAVB Cca 19x1.5 mm² FB

Nexans ref. 10567574

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 19
  • Conductor cross-section: 1.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 21.5 mm
  • Approximate weight: 786 kg/km
  • Permissible current rating in open air: 10 A
  • Permissible current rating when buried: 12 A
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

SXAVB Cca 19x2.5 mm² FB

Nexans ref. 10567575

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 19
  • Conductor cross-section: 2.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 23.3 mm
  • Approximate weight: 1010 kg/km
  • Permissible current rating in open air: 14 A
  • Permissible current rating when buried: 16 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km

 

SXAVB Cca 24x1.5 mm² FB

Nexans ref. 10567588

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 24
  • Conductor cross-section: 1.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 24.3 mm
  • Approximate weight: 942 kg/km
  • Permissible current rating in open air: 9 A
  • Permissible current rating when buried: 11 A
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

SXAVB Cca 27x1.5 mm² FB

Nexans ref. 10567629

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 27
  • Conductor cross-section: 1.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 24.7 mm
  • Approximate weight: 1004 kg/km
  • Permissible current rating in open air: 9 A
  • Permissible current rating when buried: 10 A
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

SXAVB Cca 27x2.5 mm² FB

Nexans ref. 10567577

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 27
  • Conductor cross-section: 2.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 27.3 mm
  • Approximate weight: 1339 kg/km
  • Permissible current rating in open air: 12 A
  • Permissible current rating when buried: 14 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km

 

SXAVB Cca 30x1.5 mm² FB

Nexans ref. 10567579

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 30
  • Conductor cross-section: 1.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 25.4 mm
  • Approximate weight: 1074 kg/km
  • Permissible current rating in open air: 8 A
  • Permissible current rating when buried: 9 A
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

SXAVB Cca 30x2.5 mm² FB

Nexans ref. 10567662

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 30
  • Conductor cross-section: 2.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 28.1 mm
  • Approximate weight: 1461 kg/km
  • Permissible current rating in open air: 11 A
  • Permissible current rating when buried: 12 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km

 

SXAVB Cca 37x1.5 mm² FB

Nexans ref. 10567673

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 37
  • Conductor cross-section: 1.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 27.5 mm
  • Approximate weight: 1263 kg/km
  • Permissible current rating in open air: 8 A
  • Permissible current rating when buried: 9 A
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

SXAVB Cca 37x2.5 mm² FB

Nexans ref. 10567741

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 37
  • Conductor cross-section: 2.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 30.0 mm
  • Approximate weight: 1672 kg/km
  • Permissible current rating in open air: 11 A
  • Permissible current rating when buried: 12 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km

 

SXAVB Cca 40x1.5 mm² FB

Nexans ref. 10567692

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 40
  • Conductor cross-section: 1.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 28.5 mm
  • Approximate weight: 1340 kg/km
  • Permissible current rating in open air: 8 A
  • Permissible current rating when buried: 9 A
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

SXAVB Cca 40x2.5 mm² FB

Nexans ref. 10567694

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 40
  • Conductor cross-section: 2.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 31.1 mm
  • Approximate weight: 1779 kg/km
  • Permissible current rating in open air: 11 A
  • Permissible current rating when buried: 12 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km

 

SXAVB Cca 48x1.5 mm² FB

Nexans ref. 10567695

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 48
  • Conductor cross-section: 1.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 30.7 mm
  • Approximate weight: 1536 kg/km
  • Permissible current rating in open air: 8 A
  • Permissible current rating when buried: 9 A
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

SXAVB Cca 48x2.5 mm² FB

Nexans ref. 10567571

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 48
  • Conductor cross-section: 2.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 33.7 mm
  • Approximate weight: 2056 kg/km
  • Permissible current rating in open air: 11 A
  • Permissible current rating when buried: 12 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km

 

SXAVB Cca 52x1.5 mm² FB

Nexans ref. 10567806

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 52
  • Conductor cross-section: 1.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 31.5 mm
  • Approximate weight: 1624 kg/km
  • Permissible current rating in open air: 8 A
  • Permissible current rating when buried: 9 A
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

SXAVB Cca 5x1,5 mm²

Nexans ref. 10538239

  • Packaging: Cut to length (m)
  • Armour type: Galvanised round steel wires
  • Number of cores: 5
  • Conductor cross-section: 1.5 mm²
  • Armour thickness: 1.2 mm
  • Nominal outer diameter: 14.7 mm
  • Approximate weight: 500 kg/km
  • Permissible current rating in open air: 17 A
  • Permissible current rating when buried: 21 A
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

SXAVB Cca 5x2,5 mm²

Nexans ref. 10537176

  • Packaging: Cut to length (m)
  • Armour type: Galvanised round steel wires
  • Number of cores: 5
  • Conductor cross-section: 2.5 mm²
  • Armour thickness: 1.2 mm
  • Nominal outer diameter: 15.7 mm
  • Approximate weight: 564 kg/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 28 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km

 

SXAVB Cca 61x1.5 mm² FB

Nexans ref. 10567572

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 61
  • Conductor cross-section: 1.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 33.1 mm
  • Approximate weight: 1823 kg/km
  • Permissible current rating in open air: 7 A
  • Permissible current rating when buried: 7 A
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

SXAVB Cca 61x2.5 mm² FB

Nexans ref. 10567808

  • Packaging: Cut to length (m)
  • Armour type: Steel tapes
  • Number of cores: 61
  • Conductor cross-section: 2.5 mm²
  • Armour thickness: 0.5 mm
  • Nominal outer diameter: 36.8 mm
  • Approximate weight: 2504 kg/km
  • Permissible current rating in open air: 10 A
  • Permissible current rating when buried: 10 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km

 

SXAVB Cca 7x1,5 mm²

Nexans ref. 10538233

  • Packaging: Cut to length (m)
  • Armour type: Galvanised round steel wires
  • Number of cores: 7
  • Conductor cross-section: 1.5 mm²
  • Armour thickness: 1.2 mm
  • Nominal outer diameter: 15.6 mm
  • Approximate weight: 558 kg/km
  • Permissible current rating in open air: 15 A
  • Permissible current rating when buried: 18 A
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

SXAVB Cca 7x2,5 mm²

Nexans ref. 10538234

  • Packaging: Cut to length (m)
  • Armour type: Galvanised round steel wires
  • Number of cores: 7
  • Conductor cross-section: 2.5 mm²
  • Armour thickness: 1.2 mm
  • Nominal outer diameter: 16.6 mm
  • Approximate weight: 666 kg/km
  • Permissible current rating in open air: 21 A
  • Permissible current rating when buried: 24 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km

 

Description

Description

Standards

  • National
    NBN HD 603 Part 6/Sect.E

Description

  1. Solid copper core
  2. XLPE conductor insulation (X)
  3. Filler sheath or tape banding
  4. Safety circuit in untinned copper wires (in case of steel tapes)
  5. Steel tapes or wires (A)
  6. Fire retardant PVC outer sheath (V) - grey (or black on special request)

Installation

  • In houses
  • In industries
  • Underground installation with or without protection 
  • Open air laying
  • Cable channels
  • Cable ducts
  • Only fixed installation    

Minimum Installation & Operating Temperature

Provided the conditions explained hereunder are respected, cables can be installed and operated at low temperatures down to -20°C:

Minimum Temperature during Installation

Ideally, the cable should not be installed at an ambient temperature below 5°C.  If this is not possible, the cable must be kept in a heated room of at least 20°C for 24 hours. During installation, the temperature of the sheathing must be properly monitored. If it cools down too much (below 5°C), it must be warmed up again.

Minimum Temperature during operation

The cable can operate at a minimum ambient temperature of -20°C, provided the following conditions are met:

  • the procedure for minimum temperature during installation has been respected
  • the cable has been laid according to the rules of good practice and the bending radius has been scrupulously respected during installation
  • the cable must not move at all after installation: no repositioning and certainly no exposure to vibrations.

 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor shape
Round, massive
Conductor flexibility
Solid class 1
Insulation
XLPE
Core identification
Black numbers
Material of filler / inner sheath
Compound or tape
Outer sheath
Fire-retardant PVC
Sheath colour
Grey

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/1 kV
Test voltage
4 kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Rigid
Mechanical resistance to impacts
Excellent

Usage characteristics

Usage characteristics

Bending factor when laying
15 (xD)
Field of application
Indoor, Outdoor, Underground
Max. conductor temperature in service
90 °C
Operating temperature, range
-20 - 60 °C
Minimum installation temperature
5 °C
Resistance to vibrations
No
Water proof
Water splattering

Resources

Resources

Related families

Armoured installation cables

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close