FLAMEX SI - type FXZ

Send link to this page print Your Nexans contact on this page
FLAMEX SI - type FXZ Extra flexible
Single core reinforced,
High Temperature
Standards
International  EN 50382-2; IEC 60228
Description

Application

This specific extra flexible conductor and with mechanical reinforced insulation is dedicated to be used as jumper cables

Construction

  • Conductor
    Extra Flexible class 6 copper according to IEC 60228
    * tinned copper for 120°C Class
    * plain copper for 150°C Class
     
  • Separator
    Unweaved tape
     
  • Insulation
    Twin layer of silicon rubber with included polyester reinforcement braid compound type EI 111, according to EN 50 382-1
    Colour : black

Marking

FLAMEX SI - EN 50382-2  - 3600 V - conductor size - FXZ - class temperature °C - additionnal code (R X) - Nexans - factory code - week/year

Minimum bending radius

Dynamic use : 6 x outer diameter
Static use : 4 x outer diameter
 

Standards

For performance
 

Fire Performance

  • Flame retardant : EN 50266-1
  • Smoke emission : EN 61034 light transmission > 70%
  • Fire retardant : NF C32070-2, NF 16101 class C (less than 300mm)
  • Toxicity : index IT < 3, IF index (NF F16101) IF< 5

 


 TOP
Characteristics
Construction characteristics
Halogen free EN 50267  
Usage characteristics
Chemical resistance Good  
Flame retardant EN 60332-1-2  
Smoke density EN 50268-2  
Operating temperature, range -40 .. 120°C  
Fire retardant EN 50266-2  

 TOP