TCX® (I) 331 150/250 (300)V

Send link to this page print Your Nexans contact on this page
TCX® (I) 331 150/250 (300)V "This product is part of our Shiplink® offer”
Standards
International  IEC 60092-350; IEC 60092-351; IEC 60092-359; IEC 60092-376; IEC 60298; IEC 60331; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Description

Application

TCX (I) 331 type is used on board of ships in all locations for installations complying with IEC standards 60092-352. For open decks installation, cables have to covered against UV rays. TCX (I) 331 type meets IEC 60331-21 fire resistant performances, withstands IEC 60332- 3 -22 fire test on bunched cables and performs to the SOLAS requirements.

Design

All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for intallations on passenger ships.

  1. Conductor:
    Bare copper
    Stranded class 2
     
  2. Insulation:
    Special fire resistant
    Halogen free compound
     
  3. Individual screen:
    Alu/Polyester tape with a tinned copper drain wire
     
  4. Separator:
    Polyester tape
  5. Armouring:
    Bare copper braid with bare copper drain wire
     
  6. Outer sheath:
    Polyolefin SHF1
    Colour: orange
    SHF2 on request

Type Approval Certificates


American bureau of Shipping
Bureau Veritas
China Classification Society
Det Norske Veritas
Lloyd's Register of Shipping

Core identification
 

Core 1: white

Core 2: blue

Core 3: brown

Double identification: core and pair.


 TOP
Characteristics
Construction characteristics
Conductor material Bare copper  
Conductor flexibility Stranded class 2  
Insulation HFFR special  
Screen Bare copper braid  
Outer sheath Polyolefin  
Halogen free IEC 60754-1  
Sheath colour Orange  
Drain wire Bare copper  
Protection Polyester tape(s)  
Electrical characteristics
Rated Voltage Uo/U (Um) 150 / 250 (300) V  
Usage characteristics
Fire retardant IEC 60332-3-22  
Smoke density IEC 61034  
Gases toxicity No  
Gases corrosivity IEC 60754-2  
Electro magnetic interference resistance Yes  
Fire resistant IEC 60331-21  
Max. conductor temperature in service 90°C  
Operating temperature, range -30 .. 80°C  
Standard IEC  

 TOP
Selling delivery information

Marking

NEXANS 205 TCX (I) 331* "voltage" "n" x P or T x "s" mm² 90C IEC 60332-3-22 "WW/YY" * CE * + Metric marking